For
Tube-amp builders who want a real Studio: design any tube regulator from spec, simulate, diagnose and export.
You will learn
- Compare every tube-only regulator topology on a shared bench
- Master cold-cathode VR physics, stacking and ballast sizing
- Design series + error-amp regulators with predictable Zout, ripple and stability
- Diagnose live faults (oscillation, sag, hum, no-strike) with the interactive assistant
- Export Markdown reports + SPICE netlists wired to Ampera's Koren tube models
Before you start
Power supply & rectification
Time & level
45 minAdvanced
Next step
← VR tubes catalogueTry in Designer (shunt VR) →… or as reference in series + err amp →Full Ampera page ↗
Neon indicator · Wire
NE-2 / NE-2H
Datasheet figures
- V_ref
- 65 V
- V_strike
- 90 V
- I_min
- 0.5 mA
- I_max
- 2 mA
- r_d
- 8000 Ω
- Base
- Wire
- Datasheet
- Signalite
Notes
Neon indicator, not a precision reference. Tabulated for the standard NE-2 (~90 V strike / 65 V hold); the NE-2H high-bright variant strikes higher, ~135 V, and is not separately tabulated. Sensitive to ambient light.